HVE-50 Self-Contained Portable Top Loading Autoclave w. AutoExhaust & Warming Cycle from Amerex, 120

HVE-50 Self-Contained Portable Top Loading Autoclave w. AutoExhaust & Warming Cycle from Amerex, 120
HVE-50 Self-Contained Portable Top Loading Autoclave with Auto Exhaust and Warming Cycle from Amerex

Features

  • Space-saving design with lid opening upward
  • Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature
  • Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97° C
  • Agar melting mode for melting agar and maintaining it at liquid temperature, or for a hot, faster start-up
  • One-touch lever to easily open and close chamber lid
  • In-process display shows the status and the progress of sterilization cycle
  • Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly
  • Not intended for medical use

Available Models:
 

Product Code

Description

AMEHVE-50

50 L Self-Contained, Portable, Top-Loading Autoclaves with Auto-Exhaust and Warming Cycles, Each

 

Control Panel:

HV-50 autoclave controlpanel.bmp


Included with Purchase
:

  • 1 x Autoclave Unit
  • 1 x Power Cord & Instruction Manual


Accessories for Amerex Autoclaves

 

Three different types of stainless steel containers of different heights (large, medium and small) are available for handling different loads. Stacking shorter containers can increase load capacity (two medium-sized and three small-sized containers can fit in a given chamber). A mesh wire basket is suitable for most loads, including glassware and media. A pail or a mesh wire basket with a solid bottom is used for agar and to contain potential spillage from a torn biohazard bag. A drum has a hinged lid with a handle. Depending on the load, it serves as a closed (but not watertight) trash container or as a carrying and storage case. The side and bottom of the drum are perforated for better steam penetration during sterilization. Sliding panels cover these perforations prior to and after sterilization. Round stainless steel tube racks, for tubes up to 13-mm or 20-mm tubes, are also available. You can stack tube racks by putting them inside stacked containers.

 

Optional accessories also available a) digital temperature and chart recorders, b) data logger and c) floating sensor that monitors the load temperature and sterilization timer are only activated when load temperature reaches set temperature.


Product Code

Description

AMEATA-25B2

Stainless Steel Basket (8.3” x 10.2”, D x H), Each

AMEATA-25P2

Stainless Steel Pail (8.3” x 9.8”, D x H), Each

AME ATA-25D2

Stainless Steel Drum with Hinged Lid (8.3” x 6.8”, D x H), Each

AMEATA-50B3

Stainless Steel Basket (10.7” x 8.7”, D x H), Each

AMEATA-50BSB1

Stainless Steel Basket with 5" Solid Bottom, Each

AMEATA-50P2

Stainless Steel Pail (10.7” x 10.7”, D x H), Each

AMEATA-50P3

Stainless Steel Pail (10.7” x 8.3”, D x H), Each

AMEATA-50D3

Stainless Steel Drum with Hinged Lid (10.7” x 7.1”, D x H), Each

AMEATA-TR13-90

Stainless Steel Tube Rack, Holds 90 x 13 mm Tubes, Each

AMEATA-TR20-60

Stainless Steel Tube Rack, Holds 60 x 20 mm Tubes, Each

AMEATA-85B3

Stainless Steel Basket (10.7” x 8.7”, D x H), Each

AMEATA-85BSB1

Stainless Steel Basket with 5" Solid Bottom, Each

AMEATA-85P2

Stainless Steel Pail (10.7” x 10.7”, D x H), Each

AMEATA-DL

Internal Datalogger, Each

AMEATA-HVTRD

Digital Temperature Recorder for AMEAT-HV Series Autoclaves, Each

AMEATA-TR13-90

Stainless Steel Tube Rack, Holds 90 x 13 mm Tubes, Each

AMEATA-TR20-60

Stainless Steel Tube Rack, Holds 60 x 20 mm Tubes, Each

AMEATA-TR20-126

Stainless Steel Tube Rack, Holds 126 x 20 mm Tubes, Each



Specifications:

 

AMEHVE-50

Temperature

Operating Range

105° to 135° C

Display Range

5° to 137° C

Warming Range

45° to 60° C

Gauge Pressure

Operating Range (gauge)

3 to 30 psi (0.021 to 0.206MPa)

Maximum Allowable

38 psi (0.26 Mpa)

Timer

Sterilization

1 to 250 minutes

Dimensions

Overall (W x D x H)

20.1 x 20.8 x 40.9 inches, 51 x 53 x 104 cm

Chamber Volume

50 Litres

Chamber (Diameter x Height)

11.8 x 28 inches, 30 x 71 cm

Safety Devices

Dual-sensing lid interlock, over-pressure power cut-off, over-temperature power cut-off, low-water power cut-off, mechanical pressure relief valve, lid-closure detector, over-current detector and circuit breaker

Programs

1. For Agar/Liquids. Also for melting agar, or faster start-up

Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Warming -> Completion

2. For Liquids/Solids

Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Completion

3. For Solids

Heating -> Sterilization -> Auto exhaust (fast) -> Completion

Accessories

Stainless Steel

Mesh Wire Baskets, buckets (pails) and round test tube racks

Factory or Field Installed

Data logger

Power

Source

120 V, 50/60 Hz, Single Phase (220 V available upon request)

Consumption

2,000 Watts, 2,000 VA

Shipping Weight

180 lb, 82 kg

Warranty

1 Year

 