Your cart contains  0 items
Search:
Categories
Quick Order
Last Order
Diamed # Qty.
Need more items?
  

Captair Ductless Fume Hoods - Small to Medium Capacity, 90 – 264 V

Captair Ductless Fume Hoods - Small to Medium Capacity, 90 – 264 V
Captair Ductless Fume Hoods - Small to Medium Capacity

Use Captair Smart

Erlab's 45 years of expertise in research, design and manufacturing of ductless fume hoods guarantee superior filtration that will keep you protected during your chemical processes.

Smart Technology: The new Captair Smart ductless fume hoods are designed with a simple and innovative way of communication. Smart Technology uses Smart-Light Communication to quickly see that the hood is operating safely so you can focus your attention on what is most important: your work.

Erlab's products feature the BE+ filter, the most advanced molecular filtration technology available for ductless fume hoods. Multiple chemical types can be adsorbed at the same time, so you are no longer limited to applicatoin-specific filters or the inability to adapt to new lab processes.
Safety is our first priority: Filtration and containement performance cmplay with the AFNOR NFX 15-211 standard (Class 1 and 2).

Each unit comes with Smart TechnologyTM – an exclusive set of tools that is comprised of smart-light communicationTM, chemical sensors, real-time status, and the eGuard app.
Smart-light communication is a soft band of light on the unit that lets you know the unit is operating safely. The band of light will slowly pulse to let you know if the air flow is compromised, if there is a fan failure, or there it is time to change your filters.

 


Erlab commits to guaranteeing your safety

Our safety program integrates and validates all steps to guarantee your safety: our laboratory examines your application to recommend a suitable solution and certify the use of each of our devices. Our post-installation follow-up service means you benefit from the best possible protection over time.

Enhance your user experience with eGuard APP

 

With eGuard App, the device can be monitored and controlled remotely.
The device's connectivity allows you to receive safety alerts in real time via your mobile, tablet or PC.


Overview

Total filtration of toxic gases, fumes, odors and powders
You can count on the CaptairFlex ductless fume hood to keep you safe during your chemical handlings.

It is safe, easy ot install, and provides the added benefit of low running costs. It features a phenolic resin work surface for high chemical and moisture resistance.

The containment and filtration effectiveness of the CaptairFlex make this protective equipment a reliable, economic, flexible and environmentally-friendly solution for your lab.


Only Erlab offers a ductless enclosure that guarantees safety by:
  • Adhering to the highest safety standard in the world of ductless fume hoods - AFNOR NFX 15-211:2009 as recognized by ANSI Z9.5-2012. This standard guarantees that the emissions concentration at the filter exhaust will always be lower than 1% of the Threshold Limit Value (TLV)
  • Providing a published chemical listing with the retention capacity for our filters
  • Evaluation and approval of the chemical handlings performed in the hood
  • A Certificate of Validation verifying the chemical usage, filter type, and filter lifetime.

Applications
  • Animal Perfusion
  • Dissolution
  • distillation
  • Drying
  • Evaporation
  • Extraction
  • Filtration
  • Food analysis
  • Food Safety
  • Microscopy
  • Mixture
  • TLC

How it Works

A ductless enclosure is a safety device used to protect laboratory workers when handling chemicals that pose an inhalation risk.

These enclosures are equipped with filtration technologythat is specific to the type of chemicals handled. These filters capture toxic molecules and particles evaporated in the hood and make it possible to:
  • Protect users in an effective manner
  • Reduce the carbon footprint by not releasing any toxic emissions into the atmosphere
  • Reduce operating costs due to their very low energy consumption
  • Eliminate all set-up costs related to the installation of a ducted airflow system

1 - Air intake through the openings
Air from the laboratory enters the hood through ergonomic openings. the air face velocity creates a dynamic barrier between the user and the chemicals being handled.

2 - filtration of particles and molecules
The device ventilation system draws the particles and any molecules that have evaporated in the hood toward the filtration system. The level of containment provided by the hood prevents any pollutants from being released into the laboratory.

3 - Clean air into the laboratory
The filtration technology customized to the appliation traps the molecules that have evaporated within the enclosure. The discharged air is free from all pollutants.

4 - Purification of the ambient air
The continuous recirculation of the filtered air helps to purify the ambient air of the laboratory.


Flex Technology

The unique configurable design of the filtration column makes the CaptairFlex line of ductless fume hoods adaptable to the needs of most chemical applications. The ability to stack carbon and HEPA filters allows the filtration column to be configured specifically for the applications carried out within the hood.

Features & Accessories

New Sash Option - Reverso Sash
Designed with you in mind.

The rotation of the panel allows you to optimize the total work area to meet the requirements of your applications and processes. The Reverso sash allows access to the lower or middle section of the enclosure, which provides an ergonomic position for the user.

Containment is maintained in both positions to guraantee user safety.

Control panel
Flow Monitor
This timer counts down the running hours of the unit and informs the user after every 60 hours of use to perform a saturation detection test of the molecular filter
(this feature is compliant with the AFNOR NF X 15-211: 2009 standard)

Internal lighting
18 Watts - 500 Lux - IP68 Compact fluorescent lighting. From 1 to 3 tubes needed, depending on the model.

Sampling port
It allows the user to take an air sample from the detection chamber in the filtration module in order to check the molecular filter saturation level, with the help of color coded tubes (not supplied).

Air Flow meter
It measures the air face velocity which must be between 0.4 and 0.6 m/s (this feature is compliant with the AFNOR NF X 15- 211: 2009 standard)

Energy Ports
Located on the enclosure side panels, they allow the passage of power cables/fluid pipes in the enclosure without discomfort fo the user.

Chemical Listing: The list of approved chemicals for Erlab filters
Erlab provides a booklet containing an exhaustive list of chemicals, certified by an independent test laboratory, that can be handled in the ductless enclosure in the conditions described in the aFNOR NF X 15-211: 2009 standard.

The listing contains : the chemical name, the chemical formula, CAS number, boiling point, molecular weight, and saturation vapor pressure.

This booklet also indicates the best filter option for each chemical and its retention capacity, the type of filter saturation detection system needed, the maximum quantity of the chemical that can be introduced within the enclosure.

Available Models

Product Code Description
CAPTAM321 Captair Smart 32" Ductless Fume Hood, Exterior Dimensions: 31 1/2 x 24 2/3 x min. 45 3/4 or max 53 inches (L x D x H), Each
CAPTAM391 Captair Smart 39" Ductless Fume Hood, Exterior Dimensions: 39 3/8 x 24 3/4 x min. 45 3/4 or max 53 inches (L x D x H), Each
CAPTAM481 Captair Smart 48" Ductless Fume Hood, Exterior Dimensions: 50 1/4 x 24 3/4 x min. 45 3/4 or max 53 inches (L x D x H), Each
CAPTAM632 Captair Smart 63" Ductless Fume Hood, Exterior Dimensions: 63 x 24 2/3 x min. 45 3/4 or max 53 inches (L x D x H), Each


Included with Purchase

1 x Captair Ductless Fumehood Unit (includes stainless steel work surface)
1 x POwer Cord and Instruction Manual

Accessories

Molecode S
Large spectrum filter saturation detection alarm
(Requirement for class 1 ductless fume hoods in the AFNOR NF X 15-211 : 2009 standard)
1 cell located in the detection chamber allows for the automatic detection of filter saturation by solvents.
1 cell in contact with the laboratory environment indicates ambient air poolution levels.

Mobicap
Metal mobile rolling cart equipped with 4 wheels (2 locking wheels).
Allows the safe relocation of a CaptairFlex ductless fume hood.
*only available on Captair M321 and Captair M391 models

Benchcap
Metallic fixed workbench
Equipped with two height adjusting jacks.

Shelf
Metallic adjustable sliding shelf for Mobicap™ and Benchcap™


Tempered glass work surface
With rounded edges for arm rest and a comfortable working position.

Phenolic resin work surface
Work surface with built-in retention tray, made of phenolic resin, with ergonomic edges for arm rest and a comfortable working position. High chemical and mechanical resistance. Ideal for accurate weighing operations.

Work surface in stainless steel
High chemical and mechanical resistance. Rounded corners to facilitate cleaning operations. Built in spill tray. (Only available for the models : M 321, M 391, XLS 483, XLS 714

Back panel access door
Metallic. Located on the enclosure back panel, allows for an easy rear access to heavy and bulky instrumentations. Ideal for maintenance operations. 
(Only available on CaptairFlex XL models).

Transparent back panel
Made of acrylic. Offers a 360 degree visibility in the enclosure and optimizes natural lighting.

Particulate PRe-filter
40 % filtration efficency for particles > 0.3 µm 

Erlab ductless enclosures provide total filtration of toxic gases, fumes, odors, and powders
  • Meets the containment and filtration standards of AFNOR NF X 15-211:2009 filtration safety standard as recognized by ANSI Z 9.5-2012
  • Your safety is guaranteed because we adhere to the strict process of evalulating the chemicals that will be used in the hood before approving the application. This assures applicability and provides a true filter life cycle, guaranteeing that the emissions concentration at the filter exhaust will always be lower than 1% of the TLV during normal operation
  • Automatic filter breakthrough alarm
  • Class 1 product with the addition of a second layer of filters

Performance and Flexibility
  • With Erlab's Flex Technology, you can configure the filtration that best suits our application - liquid, poweder, or liquid & powder applications
  • Select the filter that best suits your application
  • Our BE+ filter offers a high retention capacity of solvents, acids, and bases

Investment and energy savings
  • No ducting to the building ventilation system is required
  • Eliminates the energy consumption linked to the air renewal (air supply/extraction, filtration, dehumidification, air conditioning)
  • Very low energy consumption ranging from 70W to 261W

Ergonomic Design
  • New front sash is now available! Front panel pivoting on horizontal rotation axis.

Erlab's amazing filtration made easy
  • No ductwork necessary, your unit is up and running in minutes
  • Completely mobile and easy to relocate within your lab or to a new building

Energy efficient
  • No direct emission of pollutants into the atmosphere
  • We stand by our products with a lifetime warranty

Available Models

Product Code

Description

CAPTAMC321

M Series CaptAir Ductless Fume Hood, Midcap version Each

CAPTAM321

M Series CaptAir Ductless Fume Hood, Each

CAPTAM391

M Series CaptAir Ductless Fume Hood, Each

CAPTAM481

M Series CaptAir Ductless Fume Hood, Each



Included with Purchase

  • 1 x Captair Ductless Fume hood Unit (includes stainless steel work surface)
  • 1 x Power Cord & Instruction Manual


Models and Specifications:


 

CAPTAMC321

CAPTAM321

CAPTAM391

CAPTAM481

External Dimensions
(w x d x h)

 

 

 

 

Cm

80 x 63 x 116

80 x 63 x 116 mini

100 x 63 x 116 mini

127.5 x 63 x 226 mini

80 x 63 x 134.5 maxi

100 x 63 x 134.5 maxi

127.5 x 63 x 134.5 max

inches

31.5 x 24.8 x 45.6

31.5 x 24.8 x 45.6

39.4 x 24.8 x 45.6 mini

50.2 x 24.8 x 45.6 mini

31.5 x 24.8 x 53 maxi

39.4 x 24.8 x 53 maxi

50.2 x 24.8 x 53 maxi

Internal Dimensions
(w x d x h)

76.4 x 54.3 x 86.6 cm
30 x 21.4 x 34 inches

76.4 x 54.3 x 86.6 cm
30 x 21.4 x 34 inches

96.5 x 52.2 x 86 cm
38 x 20.5 x 33.8 inches

124 x 52.2 x 86 cm 48.8 x 20.5 x 33.8 inches

Metallic Parts

Anti-corrosion metallic alloy protected by a thermo-hardened anti-acid polymer coating

Side and Front Panels

8 mm thick acrylic

6 mm thick acrylic

Filtration Module

Polypropylene

Number of columns

1

Number of fans (IP44)

1

Processed Air Flow

230 m2/h

Air Velocity at the openings in working position

0.4 to 0.6 m/s

Voltage / Frequency

90 – 264 V . 50 Hz

Total Power consumption

45 Watts (without lighting)

19 – 53 Watts

19 – 71 Watts

Amperage absorbed

1.6 amp



Equipment

Standard Equipment

 

 

 

 

 

MC321

M321

M391

M481

Air Flow Meter

Permanent air face velocity monitoring system

Flow Monitor

Permanent ventilation control device according to EN 14175-2-2003 standard

 

Internal Lighting

Compact tubular fluorescent lighting – 18 Watts – 500 Lux – IP67

 

Sampling Port

For filter saturation detection (N/A if Molecode S installed )

 

Programmable Timer

Timer – 60 hours setting by default according to NFX 15 211-2009 standard

 

Energy Ports

For the passage of cables

Chemical Listing

List of approved chemicals



Optional Equipment

 

 

 

 

 

MC321

M321

M391

M481

Molecode S

Solvent Detector Alarm for Captair Smart Hoods & Storage

 

Work Surface No. 1

Tempered glass work surface with sealed frame

Work Surface No. 2

In phenolic resin with built-in retention tray

External Lighting

 

 

 

 

Mobicap

Rolling cart made of anti-corrosion metallic alloy

 

 

Benchcap

Fixed work bench made of anti-corrosion metallic alloy

Shelf

Adjustable sliding shelf for mobicap and Benchcap

Transparent back panel

Acrylic

Access door on rear panel

For maintenance interventions

 

 

Particular Pre-filter

40% filtration efficiency for particles > 0.3 µm



Types of Filters Available

GF4 AS-Type

Carbon filter for use with volatile organic compounds

GF4 BE-Type

Carbon filter for use with Acids, Organics, In-organics and bases

GF4 F-Type

For formaldehyde vapours

GF4 K-Type

For ammonia vapours

GF4 HP-Type

Hepa filter provides 99.995% efficiency for trapping 0.1 Micron particles or higher


 

 *Please select the quantity for each item you wish to order and click the 'Add To Cart' button below.
    Model   Descriptionascending   Qty   Select   Price 
   CAPTAM321   Captair Smart 32" Ductless Fume Hood, Ext. Dimensions (LxDxH): 31 1/2 x 24 3/4 x 45 3/4 (max 53")   1   Email for quote
diamed@diamed.ca
 
   CAPTAM391   Captair Smart 39" Ductless Fume Hood, Ext. Dimensions (LxDxH): 39 3/8 x 24 3/4 x 45 3/4 (max 53")   1   Email for quote
diamed@diamed.ca
 
   CAPTAM481   Captair Smart 48" Ductless Fume Hood, Ext. Dimensions (LxDxH): 50 1/4 x 24 3/4 x 45 3/4 (max 53")   1   Email for quote
diamed@diamed.ca
 
   CAPTAM632   Captair Smart 63" Ductless Fume Hood, Ext. Dimensions (LxDxH): 63 x 24 3/4 x 45 3/4 (max 53")   1   Email for quote
diamed@diamed.ca
 
Displaying 1 to 4 (of 4 products) Result Pages:  1 
Reviews